- Home
- ยป
- Our Product Range
- »
- Transformer Manufacturing and Repairing Plant
Transformer Manufacturing and Repairing Plant
Strip Re Insulating Machine for Transformer Repairing
Production Capacity | 200 Kgs |
Power Consumption | 2 H.P |
Automatic Grade | Automatic |
Brand | Sagar |
Surface | Paint Coated |
Application | Industrial |
HT Coil Winding Machine
Minimum Order Quantity: 1 Nos.
Winding Motor Power | 0.61mm to 4.50 mm |
Max Speed | 160,380,620 RPM |
Finished Coil Diameter | 300 mm |
SPECIFICATIONS H.T COIL WIDNING MACHINE
1. | Max. Coil Dia | 350 mm |
2. | Max. Coil Length | 400 mm |
3.
| Wire Dia (With Insulation) - | 0.81, 1.23, 1.331, 1.67, 1.98, 2.205, 2.464& 3.00 mm |
|
MACHINE DETIALS : |
|
4.
| Max. Weight between centers | 150 Kgs. |
5. | Winding Speed | 180, 360 & 600 RPM |
6. | Face plate dia | 2500 mm |
7. | Rod Length Dia | dia is 25 mm |
8.
| Center height over bench / Table | 250 mm |
LT Coil Winding Machine
Minimum Order Quantity: 1 Nos.
SPECIFICATION L.T COIL WINDING MACHINE
1. | Main Shaft Length | 900 mm |
2. | Center Height Over Floor | 1000 mm |
3. | Diameter of main Shaft | 32 mm |
4. | Face Plate Diameter | 250 mm |
5. | Weight carrying Capacity | 200 Kg |
6. | Motor Capacity | 2 H.P 1440 RPM CG Make |
7. | Counter Meter | Keycee Make Mechanical |
8. | Gear Box | 30:1 |
9. | Final Speed (Without VFD) | 60 RPM |
10. | End Box | Rigid With center |
11. | Foot Switch | Single with contactor |
HT Machine
Minimum Order Quantity: 1 Unit
Coil Type | round, oval, rectangular |
ire Diameter Range | 0.3 - 5mm |
Winding speed: | 160,380 and 620 RPM |
Motor power | 0.75 KW |
Max. Load (KG) | 150 Kgs |
Length of Axis (mm) | 450 |
Max.Transformer Coil (mm)Dia | 400 |
Additional Information:
- Production Capacity: 20 Sets/Month
- Delivery Time: 7 Days
- Packaging Details: main body is packaged in water-proof film for anti-rust in shipment.
Transformer Heating Chamber
Minimum Order Quantity: 1 Nos
Width : 6ft
Length : 6ft
Heating Load : 12KW
Wall Insulation : 75mm
With Trolly and Temprature Controllling Panel.
COMMON PANEL FOR TRANSFORMER TESTING
2. High voltage test using HV transformer, dimmer & common panel.
3. Open circuit and short circuit test using common panel, dimmer stat& intermediate transformer (if required & offered).
4. Magnetic balance tests using dimmer & common panel.
We are leading manufacturer in Transformer Testing Industries. We provide all instruments to test Transformer during manufacturing process as well repairing work. Testing Instruments having wide products range for Transformer Tester equipments and expert staff for quality measurement of all parameter for Transformer Tester. To Test Transformer below mention Test will conduct: NO Load Test Full Load Test Turns Ratio Test Magnetic Balance Test Vector Group Test DVDF Test High Voltage Test IR Test Winding Resistance Test Oil BDV Test Temperature rise Test Ten Delta Test
Double Voltage Double Frequency Transformer Test Set
DVDF Test Set
Double Voltage Double Frequency Test Set DVDF Test Set is Induced Over Voltage Test Set is used for testing the strength of insulation between turns and between other points of the transformers. For this test Double Voltage is applied across L.T. terminals for one minute, and to limit the magnetising current over frequency is utilised. We supply it is as mechanically coupled unit having motor and Alternator with power and control panel to regulate the output voltage. A suitable control panel is design for motor starting, generator output control, measurement of all three phases, voltage and current for input and output with protection circuit and meters.